Anats S.A. Logo

ECG ΗΕΑRΤSCRΕΕΝ 60-ΙΚΟ PORTABLE

Ecg Heartscreen 60-Ικο Portable, With 3 Channels, With Printing To Width Paper 58Mm, Lcd 58X34Mm. It Operates With Main Or Rechargeable Batteries For Continous Operation Of Printing 6 Hours And 30 Minutes. It Has Analysis Program, Low Battery Indication, Cost Effective Operation, Automatic Or Manaual Recording Mode. The Dimensions Are 25X15X7Cm And Its Weight 1.3Kg
Manufacturer: E.C.G
SKU: 211-05-005

HeartScreen 60-IKO

3-channel portable ECG device

Simple operation, basic functions from low budget.

• Good recording quality, detailed ECG curves
• Graphic LCD
• Analysis program
• 12 standard and Cabrera leads
• Large storage capacity
• Built-in real-time clock
• Sound signal for heartbeat
• Automatic or manual recording mode
• Paper-out warning
• Operation from mains and built-in
rechargeable batteries
• Low battery level indication
• Cost-effective operation
• Optional Innobase ECG database management program for archiving ECG curves and on-line 3-channel monitoring features on the PC

HeartScreen 60-IKO is a cost-effective, reliable, easy to use standard ECG device with basic functions. This small size, portable instrument makes it possible to record three ECG channels in real time. All 12 leads can be printed easily in automatic mode.
It is possible to use the lightweight, battery-operated device in the field and to store the ECG curves in its memory for later data transfer to the PC.

TECHNICAL DATA
Size and weight:
ECG device: 250 x 150 x 70 mm; 1.3 kg
Power:
› External power supply
› Mains: 90-240 V, 50/60 Hz
› Nominal power consumption: 20 VA
› Built-in rechargeable NiMh battery pack 5 cells, 6 V / min.2000 mAh
› Charging time: cca. 2.5 hours
› Low battery indication


Battery capacity:
Operating time min. 30 minutes recording or 4 hours monitoring
Leads:
Standard 12 leads
Sensitivity:
0.25 cm / mV, 0.5 cm / mV, 1 cm / mV, 2 cm /


Printing:
› Speed: 5. 25 and 50 mm / sec
› Paper width: 58 mm
› Printing resolution: 8 / 16 points/mm
› Printing modes: automatic and manual on-line
› Printing stored ECG curves in off-line mode


ECG amplifier:
› ECG specifications according to EN60601-2-25 standard
› 3-channel amplifier with 12-channel input selector
› Frequency range: 0.05 Hz ... 150 Hz, -3 dB
› CMRR: min. 100 dB
› DC tolerance: ±300 mV DC
› Input impedance: typ. 50 Mohm
› Input signal range: ±5 mV


Filters:
› Digital baseline filter
› Digital line and muscle noise filters


Safety parameters:
› Patient leakage current max. 10 μA
› Safety class “I”, “CF” according to EN 60601-1
› Defibrillator protection only with defibrillator protected cable.


Environmental requirements:
› Operating temperature: 0 ... +45 °C
› Delivery/Storage temperature: -20 … +55 °C
› Humidity: 20 ... 95% without condensation


Suggested accessories:
› 10-lead defibrillator protected cable
› Set of electrodes for adults or children
› 58 mm rastered paper
› ECG gel
› ECG carrying bag


Options:
› PC connection to USB or serial port
› Innobase database management program